REPORT 1 · AIR QUALITY READINGS

What’s in the air?
Start with what we measured.

Choose a measurement to explore the graph and see what the readings help us understand.

How to read these graphs

Longer bars show higher measured amounts. Compare locations within each graph, then read the explanation alongside it.

Carbon dioxideAir & ventilation
Carbon dioxide (ppm)
Main floor1,094 ppm
Basement1,103 ppm
Supply vent1,149 ppm

ppm = parts per million

What are we measuring?

Carbon dioxide is a gas people breathe out. We consider these readings alongside occupancy, outdoor conditions and the way fresh air moves through the home.

What does the example show?

Both rooms had similar recorded averages. The supply-vent sample was slightly higher. The readings help guide our ventilation review; they do not explain every air quality concern.

Total VOCsAirborne chemicals
Total VOCs (ppb)
Main floor290 ppb
Basement195 ppb
Supply vent313 ppb

ppb = parts per billion

What are we measuring?

VOCs are gases released by many materials and products. A total VOC reading is a broad screening measurement; it does not identify every individual chemical.

What does the example show?

The main-floor and supply-vent samples were higher than the basement sample. We consider possible sources, ventilation and whether more specific testing would help.

FormaldehydeA specific airborne chemical
Formaldehyde (ppb)
Main floor68 ppb
Basement65 ppb
Supply vent30 ppb

ppb = parts per billion

What are we measuring?

Formaldehyde is measured separately from total VOCs. The report records its concentration in each sampled area.

What does the example show?

The two room averages were close to one another, while the supply-vent sample was lower. We review the readings with the home conditions and measurement period.

Fine particulate matterSmall airborne particles
Fine particulate matter (µg/m³)
Main floor1.07 µg/m³
Basement0.78 µg/m³
Supply vent0.99 µg/m³

µg/m³ = micrograms per cubic meter

What are we measuring?

PM2.5 means fine airborne particles measuring 2.5 micrometers or smaller. This measurement shows the mass of those particles in a volume of air.

What does the example show?

The main-floor sample was higher than the basement sample during this visit. We consider filtration, particle sources and how air moves through the home.

From readings to a plan

The recommendations in this example include balanced fresh-air ventilation with an ERV, whole-home humidity control, improved filtration and HVAC cleaning. We use the readings and home evaluation together to develop a practical plan.

REPORT 2 · HOME & HVAC FINDINGS

The numbers don’t
tell the whole story.

See what a home and HVAC evaluation can uncover. Open a finding to view the photo, what we found and the recommended next step.

Blower wheel buildup & filtrationPhoto, observation & recommended next step
Close-up of buildup on a furnace blower wheel
What we found
Buildup was found on the blower wheel and inside the furnace. Gaps in the filter rack allowed air to bypass the filter.
What the evaluation adds
The report looks at the equipment and how it is being protected, rather than stopping at an air reading.
Recommended next step
Clean the affected HVAC components and correct the filter fit and sealing to address the source of the buildup.
Plugged dryer ventPhoto, observation & recommended next step
Bird’s nest blocking the inside of a dryer exhaust duct
What we found
A bird’s nest was blocking the dryer exhaust duct. An improperly connected section was also found along the vent route.
What the evaluation adds
The evaluation includes accessible exhaust routes and connections, with concerns documented in photographs.
Recommended next step
Arrange professional cleaning of the accessible vent path and affected areas, correct damaged or disconnected sections, and verify unobstructed airflow before normal use.
Moisture & exterior drainagePhoto, observation & recommended next step
Downspout extension beside the foundation
What we found
A blocked gutter, a wet area beside the home and a loose downspout extension near the foundation were documented.
What the evaluation adds
Looking at how water leaves the home helps connect exterior observations with the overall moisture evaluation.
Recommended next step
Have a gutter contractor inspect and correct the drainage, and direct the downspout discharge farther away from the home.